Hakko Thermometer / Soldering Tester
Hakko Thermometer / Soldering Tester
Hakko FG-102 Thermometer
The HAKKO FG 102 is a battery operated thermometer.It is used to measure the temperature of soldering tips.It has a compact design with good portability.It enables high precision temperature measurement free of human and transcription errors.
Standardized measurement of temperature is possible.It measures temperature between 0 to 700°C.It enables very easy management and transfer of the recorded temperature data to computers.It has a power saving mode which ensures longer battery life.
It automatically indicates the calibration date for the thermometer.
Hakko FG-102 Thermometer
A new proposal for improvement and labor-saving in tip temperature control, from measurement to records management, for enhancement of manufacturing quality.
Features
- Aim for free of errors in recoding and for labor-saving by scanning unit ID and operator ID
Support to achieve labor-saving in tip temperature control by elimination of a manual process of posting measured temperature and inputting records into computer. |
Support to achieve free of errors in temperature measurement by standardization of temperature measurement |
|
The unit has a function to notify the end of measurement. When measurement is finished, “H” icon stops blinking. The unit can find measurement errors and prompt an operator to repeat measurement. The display shows “Fail” if tip loses appropriate contact with sensor before completion of measurement. | |
Pass/Fail judgment on measured temperature |
|
Pass/Fail judgment on measured temperature can be automatically made if an acceptable temperature range is registered in advance. (The display shows “OK” or “Fail”.) |
- Make it easy to manage tip temperature records by transferring the data to computer
The unit can save up to 300 measurement records and transfer the data to computer via USB. (Data in CSV format. USB cable included.) |
- Group control
Groups can be created based on different set temperatures for different operations. Pass/Fail judgment on measured temperatures can be automatically made for different acceptable temperature ranges. |
- Automatic counting of the number of measurements
The unit automatically counts the number of measurements which indicates the timing of sensor replacement. The picture is showing the display after measuring 6 times. |
- Notification of the calibration date
The unit automatically notifies the next scheduled calibration date if it is registered. When the power is tuned on, this screen is displayed from two weeks before the calibration date. Example: If the next calibration date is January 15, 2015, the screen is displayed from January 1, 2015.
|
- Power saving design
The unit will automatically enter power save mode if not in operation for a certain time. Power supply to the scanner can be shut off when it is stored in the holder and battery consumption can be reduced. |
- Portability
Excellent portability with a handle and no need for power supply cord. Compact design makes it easy to carry a unit around in workplace. |
Specifications
Model No. | FG-101B |
Power Supply | AA sized (LR6) battery × 6 (alkaline cell recommended) |
Temperature Resolution | 1ºC |
Temperature Measurement Range | 0 to 700ºC |
Temperature Precision | ±3ºC (300 to 600ºC) ±5ºC (other than above) |
Temperature Sensor | K (CA)type thermocouple |
Display | LCD |
Voltage Measurement range | 0 to 40 mV |
Voltage Accuracy | ±(5% of reading + 1 digit) |
Resistance Resolution | 0.1 Ω |
Resistance Measurement range | 0 to 40 Ω |
Resistance Accuracy | ±(5% of reading + 1 digit) |
Display | LCD : 3.5 digits |
Operating Environment | Ambient temperature / Humidity range : 0 to 40ºC, max.80% RH (without condensation) |
Environmental Conditions | Applicable rated pollution degree 2 (according to IEC/UL 61010-1) |
Dimensions | 193(W)× 90(H)× 219(D)mm |
Weight | 0.93kg |
* Dimensions : excluding barcode reader
* Weight : excluing battery and barcode reader
* Temperature sensor (No.191-212 or No.191-212C) can only be used ti measure temperatures below 500ºC. To measure higher temperatures, use an applicable temperature probe.
* Traceability management function can only be used for soldering irons.
Hakko FG-101 B Tester
Soldering iron tester for measurement of tip temperature, leak voltage, and tip to ground resistance
Features |
|
For the daily maintenance of soldering station Control of “tip temperature”, “leak voltage”, and “tip to ground resistance” is required for a grounded soldering station for electronic components. |
|
Human error-free operation | |
|
|
Long life sensor AS5000(with certificate of conformance) is equipped as standard Possible to measure tip temperature faster with high accuracy. Approximately 30 times longer than the conventional sensor |
|
MAX HOLD Function (Temperature measurement) Max measured tip temperature will be displayed. This function can be useful for quality control of components and P.W.B. |
|
Temperature Measurement Count Function Number of tip temperature measurement will be automatically counted. This function can be useful for control of changing sensor. |
|
AUTO ZERO Function The zero point error of measuring instruments can be corrected by simply pressing the AUTO ZERO button and waiting for the display to return to normal. |
|
Temperature probe Use of a temperature probe makes it possible to measure the temperature of molten solder in a solder pot and hot air. |
|
Specifications
Model No. | FG-101B |
Power Consumption | 3.6 W (220-240 V) |
Temperature | 1ºC |
Temperature Measurement Range | 0 to 700ºC |
Temperature Accuracy | ±3ºC (300 to 600ºC) ±5ºC (other than above) |
Temperature Sensor | K (CA) type thermocouple |
Voltage Resolution | 0.1 mV |
Voltage Measurement range | 0 to 40 mV |
Voltage Accuracy | ±(5% of reading + 1 digit) |
Resistance Resolution | 0.1 Ω |
Resistance Measurement range | 0 to 40 Ω |
Resistance Accuracy | ±(5% of reading + 1 digit) |
Display | LCD : 3.5 digits |
Operating Environment | Ambient temperature / Humidity range : 0 to 40ºC, max.80% RH (without condensation) |
Environmental Conditions | Applicable rated pollution degree 2 (According to IEC/UL 61010-1) |
Dimensions | 211 (W) × 53 (H) × 126 (D) mm |
Weight | 0.95 kg |
Hakko FG-100 B Thermometer
Automatic measurement to standardize the process. Minimize individual differences in how to complete measurement and read result.
Features |
|
Automatic temperature measurement:AUTO HOLD Function The measurement will end automatically when tip temperature is stabilized. The measurement process will be the same no matter who does it |
|
Constant display of measured max. temperature:MAX HOLD Function Max measured tip temperature will be displayed. This function can be useful for quality control of components and P.W.B. |
|
Temperature Sending Function By infrared communication, FG-100B can send temperature measurement results by AUTO HOLD function or MAX HOLD function to a soldering station (FN-1010, FX-805) with an IR receiver. Image photo below AUTO HOLD function and MAX HOLD function cannot be used at the same time. |
|
Long life sensor AS5000(with certificate of conformance) is equipped as standard
|
|
[Conventional Sensor(191-212] Approx. 9 sec. |
[New Sensor (AS5000]Approx. 3 sec |
Temperature Measurement Count Function Number of tip temperature measurement will be automatically counted. This function can be useful for control of changing sensor. |
|
Auto Shutoff Function It will automatically turn the power off if a measured temperature does not exceed 100℃ for 3 minutes. It saves battery power and time for changing the battery. |
|
Accessible from any direction Allows you to measure from any desired direction according to tip shape. |
|
Several ways of measurement can be possible with temperature probes. (Option) | |
For soldering pot A1310 |
For hot air station C1541 |
Specifications
Model No. | FG-100B |
Power supply | 006P 9 V dry battery (alkaline cell recommended) |
Temperature Resolution | 1ºC |
Temperature Measurement Range | 0 to 700ºC |
Temperature Accuracy | ±3ºC (300 to 600ºC) ±5ºC (other than above) |
Temperature Sensor | K (CA)type thermocouple |
Display | LCD : 3.5 digits |
Operating Environment | Ambient temperature/humidity range : 0 to 40ºC, max.80% RH (without condensation) |
Environmental Conditions | Applicable rated pollution degree 2 (According to IEC/UL 61010-1) |
Dimensions | 75 (W) × 44 (H) × 140 (D) mm |
Weight | 125 g |
Industries Powered By Soldering Stations